[<<Previous Entry]
[^^Up^^]
[Next Entry>>]
[Menu]
[About The Guide]
Int 1A Fn 82 - PCmcia Socket Services - Register Card Technology Callbac [X]
AH = 82h
DS:DX -> callback routine (see below) or 0000h:0000h
Return: CF clear if successful
AH destroyed
CF set on error
AH = error code (see AH=80h"PCMCIA")
Note: the callback is invoked on a Write Multiple request with an unsupported
card technology type
See Also: AH=81h"PCMCIA",AH=94h
Callback routine invoked with:
ES:AX -> Low-Level Socket Services Routines (see below)
BH = socket attributes (see below)
CX = number of bytes or words to write
DS:SI -> data buffer to be written
DX:DI -> 26-bit linear card address
BP = card technology type
Return: CF clear if successful
CF set on error
AH = error code (07h,0Ch,12h,14h) (see AH=80h"PCMCIA")
Bitfields for socket attributes:
bit 0 memory type (clear = common, set = attribute)
bit 1 data width (clear = byte, set = word)
bit 2 even bytes only (only valid if bit 1 set)
bit 3 packed buffer
bits 4-7 reserved (0)
Format of Low-Level Socket Services Routines:
Offset Size Description
00h WORD offset of Write Many routine (see below)
02h WORD offset of Write One routine (see below)
04h WORD offset of Read One routine (see below)
06h WORD offset of Increment Offset routine (see below)
08h WORD offset of Set Offset routine (see below)
0Ah WORD offset of Get Status routine (see below)
Call Write Many routine with:
BH = socket attributes (see above)
CX = number of bytes or words to write
DS:SI -> data to be written
Return: CF clear if successful
CF set on error
Call Write One routine with:
AL/AX = data to be written
BH = socket attributes (see above)
Return: CF clear if successful
CF set on error
Call Read One routine with:
BH = socket attributes (see above)
Return: CF clear if successful
AL/AX = data read
CF set on error
Call Increment Offset routine with:
BH = socket attributes (see above)
Return: CF clear if successful
CF set on error
Call Set Offset routine with:
DX:DI = new offset address
Return: CF clear if successful
CF set on error
Call Get Status routine with:
nothing
Return: AL = current card status (see AH=81h"PCMCIA")
This page created by ng2html v1.05, the Norton guide to HTML conversion utility.